Welcome to the official website of Zhoukou General Blower Co., LTD

Home>Product>Centrifugal fan
F9-28 I Anti-corrosion centrifugal fan

F9-28 I Anti-corrosion centrifugal fan
Product category:Centrifugal fan

Product introduction

F9-28 Type I Anti-corrosion Centrifugal Fan Application:

F9-28 I-type anti-corrosion centrifugal fan is generally used in forging and high-pressure forced ventilation, and is widely used in material transportation, and can be used to transport air and five corrosive, non-self-igniting, and non- viscous gases. The temperature of the conveying medium generally does not exceed 80 degrees Celsius, and the dust and hard fine particles contained in the ring are not more than 150 mg/cubic. The fan can also be used as a high-temperature fan used in special occasions such as cement cellar decomposition work and steel smelting.

F9-28 I type anti-corrosion tail gas centrifugal fan type:

1. The fan is available in two types: single-suction and double-suction. There are 20 machine numbers including No4, 4.5, 5, 5.6, 6.3, 7.1, 8, 9, 10, 11.214, 16, 17, 18, 20, 21, 22, 23, and 24.

2. The fan can also be made into two types of right-handed or left-handed; if the impeller rotates clockwise when viewed from the front of the motor (or main shaft), it is called a clockwise fan, which is represented by "shun"; if the impeller rotates counterclockwise, It is called reverse fan, and it is represented by "reverse".

3. The outlet position of the fan is represented by the outlet angle of the casing, "left" and "right" can be made into six angles of 0 degree, 45 degree, 90 degree, 135 degree, 180 degree and 225 degree.

4. The transmission mode of the fan is A type (machine number 4-6.3), D type (machine number 7.1-16) and F type.

F9-28 I type anti-corrosion tail gas centrifugal fan structure:

No.4~6.3 of the fans are mainly composed of impellers, casings, air inlets, brackets, etc. No.7.1~24 of fans are composed of impellers, casings, air inlets, transmission groups , etc. F-type transmissions are mainly composed of impellers, It is composed of casing, air intake box, transmission group , etc. The fan can also be equipped with an adjustable door according to the needs of users. The impeller of 1.9-28I fan has 16 long blades and 16 short blades.

2. The casing is welded with ordinary steel plates to form a volute as a whole. For high-temperature fans, heat-resistant materials can be selected according to the temperature. The casing can also be made into splits.

3. The air inlet is made into a convergent and streamlined overall structure, which is fixed with bolts and the front cover plate.

4. The transmission group is composed of main shaft, bearing box, coupling and so on.

 

The flow range of the fan is 2,200 cubic meters - 300,000 cubic meters/h (single suction), 600,000 cubic meters/h (double suction), and the pressure range is 350kg/ square - 200Kg/square

F9-28 I type anti-corrosion centrifugal fan parameters:

 

 

machine number

no

transmission

Way

Rotating speed

r/

min

Full pressure

Pa

flow

m³/h

internal efficiency

Internal power

KW

required power

KW

 

motor

 

 

 

 

12.5

 

 

 

 

 

 

D

 

 

 

 

 

 

960

 

 

5164

22200

81.5

31.54

37.8

 

Y280S-6

45KW

5158

24980

82.6

34.92

40.9

5101

27760

82.6

38.36

45.1

5040

30590

81.0

41.80

49.2

4917

33300

81.1

45.32

53.2

 

Y315S-6

75KW

4884

36093

80.0

48.87

57.0

4799

38870

78.3

52.31

61.5

4689

41,732

76.4

55.58

65.8

 

 

 

 

14

 

 

 

 

D

 

 

 

 

960

5530

34289

81.5

55.89

69.02

 

Y325S-6

75KW

5528

35107

82.6

61.73

72.13

5460

39076

82.6

67.84

74.09

5309

42943

82.0

73.64

87.37

 

Y315M-6

110KW

5288

46832

81.1

80.21

94.68

5181

50743

80.0

85.92

102.7

5063

54681

78.3

92.74

107.8

4998

59303

76.4

99.05

110.3

 

machine number

no

transmission

Way

Rotating speed

r/

min

Full pressure

Pa

flow

m³/h

internal efficiency

Internal power

KW

required power

KW

 

motor

 

 

 

 

16

 

 

 

 

D.

 

 

 

 

960

7335

46580

81.5

110.5

129.3

 

Y355M-6

160KW

7318

52381

82.6

122.0

142.8

7229

58277

82.6

133.7

156.6

7121

64098

82.0

146.6

170.4

 

Y355M-6

250KW

7001

69903

81.1

157.5

184.5

6864

75701

80.0

169.2

198.2

6709

81503

78.3

181.4

212.6

6596

87425

76.4

194.4

227.8

 

 

 

 

17

 

 

 

 

 

 

D

 

 

 

 

 

 

960

 

 

7703

55933

81.5

148.8

170.7

 

Y355M-6

220KW

 

7728

62952

82.6

164.6

188.9

7630

69931

82.6

179.4

207.6

7493

76901

82.0

192.1

220.1

7381

83872

81.1

209.3

243.2

 

Y355M-6

280KW

7291

90995

80.0

225.7

262.8

7106

97872

78.3

242.4

283.3

6910

104831

76.4

258.1

303.8

 

machine number

no

transmission

Way

Rotating speed

r/

min

Full pressure

Pa

flow

m³/h

internal efficiency

Internal power

KW

required power

KW

 

motor

 

 

 

 

18

 

 

 

 

 

 

D

 

 

 

 

 

 

730

 

 

5517

50594

81.5

86.17

100.8

 

 

 

Y355S-8

185KW

5505

57193

82.6

95.42

111.6

5442

63692

82.6

104.6

122.1

5357

69795

81.0

114.0

133.2

5278

76692

81.1

123.8

144.9

5175

82390

80.0

132.9

155.5

5061

88689

78.3

142.6

166.9

5001

94989

76.4

152.8

178.7

 

 

 

 

20

 

 

 

 

D

 

 

 

 

730

6300

69170

81.5

146.1

 

 

 

Y355S-8

220KW

 





 


——Related Product——

Mobile phone:0086-15539485098

Factory address:37 Zhouxi Road, Chuanhui District, Zhoukou City, Henan Province, China

Zhoukou General Blower Co., LTDWechat customer service
Online customer service
Service hotline

Service hotline

0086-15539485098

Wechat consultation
Zhoukou General Blower Co., LTDWechat
Douyin video
Zhoukou General Blower Co., LTDDouyin
Return to the top